Main Items
Site Survey completed and approved by VergeIO
ISO downloaded and installed on a USB drive
Encryption Key USB installed and ready (if enabling at-rest encryption)
Nodes powered up with ISO booted to VergeIO Install screen
Crash cart ready if applicable
Remote screen share capability or remote IPMI access (WAN or VPN)
¶
Hardware
Hardware burn-in complete
All Drives setup for JBOD,
NO RAID
BIOS set to proper boot settings (Legacy / Dual / UEFI)
UEFI is required if all drives are NVMe
BIOS clocks set correctly
Redundant Power supplies setup and connected (recommended)
IPMI ports patched and configured
IPMI setup / configured / tested
Latest IPMI firmware (recommended)
Test IPMI remote console capability (in case of incorrect licensing)
¶
Network
All switches online and tested
All cables patched
All VLANs configured (core - required, external - optional)
Each Core switch should be on a dedicated VLAN (ex 101 for core 1, 102 for core 2)
All switch ports configured (core and external)
External Bond ports setup correctly if bonding external (do not bond Core)
2 NICs per node minimum and separate switches
Correct Supported SFP modules (if applicable)
Correct IPs validated and available
Correct Gateway IP tested/pingable